Movements monitoring of the CMS Tracker detector during the cooling procedure with the Laser Alignment System

No programado
20m
Valencia, Spain

Valencia, Spain

Poster Detector RD and Performance

Ponente

Adrian Perieanu

Descripción

The Laser Alignment System (LAS) of the CMS Tracker detector monitors the position variation of its components every five minutes. A precision of 1 micrometer for the x and y translations, and 1.1 microradians rotation around z-axis was achieved. For rotations around x- and y-axis the achieved precision is 3.7 and 2.6 microradians, respectively. During the cooling down test performed in November 2013, the Tracker internal structure was monitored and movements of thermal nature were observed. Using the tracks-based alignment algorithm, Millepede, the LAS-derived alignment parameter variations were cross-checked with cosmic rays. The results obtained from both alignment strategies, LAS and tracks based, are presented. The consistency of the alignment parameters variations is discussed.