Considering the upcoming HL-LHC, the Phase-2 CMS upgrade is set to revamp the trigger and data acquisition system. Upgrading the readout electronics to handle a maximum L1 accept rate of 750 kHz and a latency of 12.5 µs.The muon trigger is a multi-layered system designed to reconstruct and measure muon momenta by analyzing data from muon chambers using advanced pattern recognition algorithms running on FPGA processors. The Layer-1 Barrel Muon Filter is the second layer of this system. It focuses on consolidating data from barrel muon stations and refining it before sending it to the main trackers.We describe the first version of an algorithm meant to detect and identify muon showers. This algorithm has been tested in firmware, and its performance in physics has also been evaluated, with over 95% detection rate.