BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Reunión GEFM y MESA REDONDA: Cómo podemos mejorar la interacció
 n entre físicos y radiofísicos?
DTSTART;VALUE=DATE-TIME:20170719T163000Z
DTEND;VALUE=DATE-TIME:20170719T170000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4534@indico.ific.uv.es
DESCRIPTION:Speakers: Gabriela Llosa (IFIC-CSIC)\nhttps://indico.ific.uv.e
 s/event/2851/contributions/4534/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4534/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Hamamatsu - News
DTSTART;VALUE=DATE-TIME:20170719T170000Z
DTEND;VALUE=DATE-TIME:20170719T171000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4523@indico.ific.uv.es
DESCRIPTION:Speakers: David Castrillo ()\nhttps://indico.ific.uv.es/event/
 2851/contributions/4523/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4523/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Aplicación de métricas de distancia en el análisis de imágenes
  de bandas oligoclonales para el diagnóstico precoz de la Esclerosis Múl
 tiple
DTSTART;VALUE=DATE-TIME:20170719T154500Z
DTEND;VALUE=DATE-TIME:20170719T160000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4405@indico.ific.uv.es
DESCRIPTION:Speakers: Marina Rosales-Martinez (Universidad de Sevilla)\nEl
  trabajo que se presenta comprende el diseño y evaluación inicial de nue
 vos biomarcadores de esclerosis múltiple mediante análisis de las bandas
  oligoclonales obtenidas a partir de la digitalización y procesado de las
  imágenes de membranas electroforéticas en una prueba estándar. Se comp
 aran las secuencias de bandas de pacientes con diagnóstico inicial de sí
 ndrome neurológico aislado para predecir su evolución hacia esclerosis m
 últiple clínicamente definida mediante múltiples métricas de distancia
 .\n\nhttps://indico.ific.uv.es/event/2851/contributions/4405/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4405/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Evaluación de dimensiones de mallado para la simulación 3D de la
  propagación de ultrasonidos en medios fluidos para aplicaciones médicas
DTSTART;VALUE=DATE-TIME:20170719T160000Z
DTEND;VALUE=DATE-TIME:20170719T161500Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4403@indico.ific.uv.es
DESCRIPTION:Speakers: Emilio Gomez-Gonzalez (Universidad de Sevilla)\nLos 
 métodos de análisis y diagnóstico mediante haces de ultrasonidos son mu
 y variados y se utilizan habitualmente en multitud de áreas científicas\
 , industriales y médicas. Entre ellos\, destacan por su rápido desarroll
 o\, las técnicas de cirugía no invasiva mediante ultrasonidos enfocados\
 , con numerosas aplicaciones en oncología\, neurocirugía\, neurología y
  otros ámbitos clínicos. El cálculo numérico de los campos de presión
  generados por emisores de ultrasonidos permite evaluar y\, especialmente\
 , visualizar de forma gráfica\, las zonas de concentración y los efectos
  de refracción\, reflexión y difracción que puedan producirse en las re
 giones por las que se propagan las ondas. Uno de los aspectos prácticos m
 ás relevantes al resolver este tipo de problemas mediante el método de l
 os elementos finitos es la discretizacion del dominio y generación del ma
 llado espacial tridimensional para el cálculo. Se encuentra el tamaño m
 áximo o longitud característica de la unidad mínima del mallado en rela
 ción con la longitud de onda.\n\nhttps://indico.ific.uv.es/event/2851/con
 tributions/4403/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4403/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Comportamiento dosimétrico tras una parada prolongada y nueva pue
 sta en marcha del acelerador lineal de electrones móvil MOBETRON
DTSTART;VALUE=DATE-TIME:20170719T161500Z
DTEND;VALUE=DATE-TIME:20170719T163000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4369@indico.ific.uv.es
DESCRIPTION:Speakers: Francisco Javier de Luis Pérez (Hospital Quironsalu
 d. Universidad Católica San Antonio Murcia)\nIntroducción\nEl Hospital Q
 uirónsalud Torrevieja cuenta desde el año 2004 con un acelerador lineal 
 de electrones móvil MOBETRON para uso específico en radioterapia intraop
 eratoria (RIO). Este acelerador móvil no necesita de una sala blindada\, 
 ni de una infraestructura específica [1]\, por lo que está situado en un
 o de los quirófanos del hospital. De esta forma se puede tratar el lecho 
 quirúrgico de los pacientes evitando el traslado de los mismos a un búnk
 er de radioterapia convencional. Una de las ventajas de la RIO es que se p
 uede evitar\, en una única sesión\, y dependiendo de la lesión\, un tra
 tamiento posterior de radioterapia convencional que puede alargarse hasta 
 cinco semanas. Esto es posible para cualquier localización del tumor\, en
  especial en el tratamiento del cáncer de mama.\nTras una parada prolonga
 da se ha requerido de una nueva puesta en marcha del equipo en la que hemo
 s estudiado la alteración de los diferentes parámetros dosimétricos.\n\
 nMaterial y Método\nEl acelerador móvil de electrones sobre el que se ha
  trabajado es un MOBETRON de la serie 1000 [2]\, de la firma IntraOp Medic
 al Corp. Para su puesta en marcha se ha contado con la ayuda de los ingeni
 eros de esta misma firma\, la cual se encargó de su diseño\, fabricació
 n e instalación.\nEl acelerador cuenta con cuatro energías nominales dis
 ponibles\, de 4\, 6\, 9 y 12 MeV [3]. Y con una tasa de dosis máxima de 1
 000 UM/min. Tras una revisión pormenorizada de los circuitos de refrigera
 ción y vacío se verificó por parte del fabricante el ajuste del haz de 
 radiación y la tasa de dosis estable de funcionamiento conseguida para ca
 da energía. Se analizó la constancia de dosis y energía con el sistema 
 de control de calidad de que dispone el acelerador\, en los rangos Rmáx y
  R50\, con un conjunto cámara farmer 30013 y un electrómetro UNIDOS E de
  PTW. Se realizaron medidas en agua de los rendimientos de dosis en profun
 didad y de los perfiles de dosis a la profundidad del máximo\, con cuba M
 P3 de PTW y diodos Scanditronix y Wellhofer AB\, caracterizando la simetr
 ía [4] y homogeneidad de cada una de las energías. Por último y en mani
 quí de agua plástica se midió la dosis absoluta con cámara plano-paral
 ela ROOS y se establecieron nuevas dosis de referencia.\n \nResultados\nPa
 ra la energía de 4 MeV\, no ha sido posible establecer un ajuste que perm
 itiese un funcionamiento estable a tasas cercanas a la de uso clínico de 
 1000 UM/min. Dado que este ajuste hubiese comprometído al resto de energ
 ías y como además esta energía carece de interés clínico (sólo ha si
 do utilizada en un paciente desde el comienzo de actividades) se ha optado
  por suspender su uso. Para el resto de energías si ha sido posible estab
 lecer ajustes estables de funcionamiento del haz con tasas próximas a 100
 0 UM/min.\nEn cuanto a la energía\, sólo ha sido necesario hacer un lige
 ro ajuste de la de 9 MeV. Tanto los haces de 6 MeV como los de 12 MeV se h
 an mantenido estables respecto a los establecidos antes de la parada.\nRes
 pecto a la constancia de dosis en los rangos Rmáx y R50 se observó que s
 e mantenía constante\, con ligeras desviaciones respecto de las medidas d
 e referencia de que se disponía antes de la parada del equipo.\nSe compro
 bó que tanto la simetría como la homogeneidad que presentaban los perfil
 es a la profundidad de máxima dosis absorbida\, estaban dentro de toleran
 cias\, quedando pendiente una posterior verificación mediante placa radio
 gráfica.\nLos nuevos valores de dosis de referencia obtenidos mediante do
 simetría absoluta con maniquí de agua plástica\, están en concordancia
  con los establecidos en el estado de referencia previo a la parada del eq
 uipo.\n\nConclusiones\nSe ha logrado poner en marcha el acelerador móvil 
 MOBETRON después de un periodo de parada muy largo (superior a 3 años). 
 La intervención del fabricante para esta puesta en marcha ha sido menor d
 e lo previsible inicialmente. La estabilidad del equipo desde el punto de 
 vista dosimétrico ha sido muy buena requiriendo tan sólo un ligero ajust
 e de energía para el haz de 9 MeV\, restituyendo el equipo a su estado de
  referencia previo a la parada. De hecho la dosis de referencia ha permane
 cido constante respecto a los valores registrados previos a la parada del 
 equipo y en concordancia con los valores de constancia establecidos en la 
 literatura [4].\n\nAgradecimientos\nExpresar nuestro agradecimiento a Intr
 aOp Medical Corp. Por el soporte proporcionado al poner en marcha el equip
 o. También queremos expresar nuestro agradecimiento a todo el personal de
  quirófano por su apoyo y colaboración.\n\nReferencias\n[1] Intraoperati
 ve radiation therapy using mobile electron linear accelerators: Report of 
 AAPM Radiation Therapy Committee Task Group Nº72.\n[2] M.D. Mills\, L.C. 
 Fajardo\, D.L.Wilson\, J.L.Daves\, W.J.Spanos. Commissioning of a mobile e
 lectron accelerator for intraoperative radiotherapy. Journal of Applied Cl
 inical Medical Phys. (2001) Volume 2\, Number 3.\n[3] L.S. Wootton\, J. Me
 yer\, E. Kim\, M. Phillips. Commissioning\, clinical implementation\, and 
 performance of\nthe Mobetron 2000 for intraoperative radiation therapy. Ra
 diation Oncology Phys. DOI: 10.1002/acm2.12027.\n[4] Beddar AS. Stability 
 of a mobile electron linear accelerator system. Med. Phys.(2005) Volume 32
 \, Number 10.\n\nhttps://indico.ific.uv.es/event/2851/contributions/4369/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4369/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Estimación del ángulo de Cobb con métodos aprendizaje máquina 
 a partir de imágenes topográficas de la superficie de la espalda\, obten
 idas con luz estructurada
DTSTART;VALUE=DATE-TIME:20170719T151500Z
DTEND;VALUE=DATE-TIME:20170719T153000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4340@indico.ific.uv.es
DESCRIPTION:Speakers: Rosa M Cibrian (Biofísica y Física Médica. Dpto. 
 de Fisiología. Universitat de València)\nEl aprendizaje máquina (machin
 e learning) ofrece algoritmos y procedimientos inteligentes para abordar a
 nálisis complejos de datos\, los cuales han servido para la implementaci
 ón de sistemas de ayuda a la decisión en una variedad de aplicaciones de
 ntro de diversas áreas médicas. En este trabajo se ha aplicado para el d
 iagnóstico y seguimiento de la escoliosis idiopática. Esta patología fr
 ecuente en la adolescencia se caracterizada por el valor del ángulo de Co
 bb medido en la radiografía del paciente. Ahora bien\, la dosis repetida 
 de radiación ionizante\, a la cual están expuestos estos pacientes en ed
 ades más radiosensibles\, puede representar riesgos para su salud futura.
 \nLa topografía de superficie de la espalda es una propuesta que la propi
 a SOSORT (International Society on Scoliosis Orthopaedic Rehabilitation an
 d Treatment) resalta como prueba complementaria para documentar la deformi
 dad asociada con la escoliosis. No obstante\, existen diversas técnicas t
 opográficas que tratan de valorar la deformidad\, mediante índices topog
 ráficos diferentes\, por lo que muchas veces no son comparables entre sí
  y no facilita un consenso para que estas técnicas sean útiles en la pr
 áctica clínica habitual. Por ello\, el objetivo de este trabajo es la ut
 ilización de modelos de aprendizaje máquina para estimar el ángulo de C
 obb a partir de variables topográficas obtenidas con un método no lesivo
  basado en la proyección de luz estructurada. \nEl modelo con mejores res
 ultados ha sido el Random forest (RF). Los valores estimados del ángulo d
 e Cobb con este modelo\, aplicado a todos los casos\, permite clasificar a
  los pacientes como patológicos si el Cobb calculado es mayor o igual a 1
 0º\, con índices de fiabilidad diagnóstica: sensibilidad=0.97\, especif
 icidad=0.79\, valor predictivo positivo=0.92 y valor predictivo negativo=0
 .91\, que avalan la capacidad diagnóstica del método.\n\nhttps://indico.
 ific.uv.es/event/2851/contributions/4340/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4340/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Bioimagen coherent en free-electron lasers: éxitos y retos
DTSTART;VALUE=DATE-TIME:20170719T133000Z
DTEND;VALUE=DATE-TIME:20170719T134500Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4255@indico.ific.uv.es
DESCRIPTION:Speakers: Pablo Villanueva Perez (DESY-CFEL)\nLos free-electro
 n lasers han supuesto una gran revolución en el ámbito de la imagen cohe
 rente\,\npermitiendo explorar simultáneamente resoluciones espaciales y t
 emporales en torno al ångström y\nel femtosegundo. Además\, dado que ge
 neran un haz coherente en el espectro de los rayos X\,\npermiten utilizar 
 técnicas de imagen coherente similares a las utilizadas con láseres en e
 l visible.\nConcretamente\, estas técnicas tienen el potencial de fotogra
 fiar células y sistemas biológicos con\nresoluciones atómicas y filmar 
 películas de procesos con 10 15 fotogramas por segundo. En esta\npresenta
 ción discutiremos los últimos resultados obtenidos con técnicas coheren
 tes desarrolladas\npara obtener imágenes de sistemas biológicos en free-
 electron lasers. Finalmente\, mencionaremos\nlas limitaciones\, retos y po
 sibles soluciones de estas técnicas utilizadas en free-electron lasers pa
 ra\nbioimagen.\n\nhttps://indico.ific.uv.es/event/2851/contributions/4255/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4255/
END:VEVENT
BEGIN:VEVENT
SUMMARY:High throughput production of solid targets for laser-driven parti
 cles acceleration through MEMS based processing.
DTSTART;VALUE=DATE-TIME:20170719T140000Z
DTEND;VALUE=DATE-TIME:20170719T141500Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4205@indico.ific.uv.es
DESCRIPTION:Speakers: rosa letizia zaffino (instituto de microelectronica 
 de barcelona\, IMB-CNM)\nLaser-driven particle acceleration is reasonably 
 feeding the hope for the development of compact particle accelerators rely
 ing on the ultra-intense interaction established when a high power\, ultra
 -short\, laser (HPL) pulse is focused on a very tiny area of a solid targe
 t surface. [1]. Laser-driven ion acceleration has been observed since earl
 y experiments of solid target irradiation with lasers\, and it has been ex
 plained in the framework of Target Normal Sheath Acceleration (TNSA) model
 . Particle acceleration originates from the rear surface of a solid target
 \, typically a thin metallic foil\, and is caused by the charge separation
  field generated by laser-plasma interaction on the front target surface a
 t laser intensities of 1018÷1020 W/cm2 (Fig.1 (a)). Until now\, targets s
 upply strategies have been principally based on fabrication and assembly o
 n an individual basis. However\, this approach is not suitable to exploit 
 the full potential of high repetition rate HPLs. Therefore\, the developme
 nt of high throughput target fabrication processing for ultra-intense lase
 r-plasma experiments is receiving many efforts. In this regard\, the appro
 ach based on micro-/nano-electromechanical systems (N/MEMS) technology\, w
 hich evolved from semiconductor device manufacturing\, is a very attractiv
 e solution [2]. It provides\, in fact\, parallel processing and the possib
 ility to achieve complex target design with micro-nano sized features on a
  variety of materials.\nHere\, we present the fabrication of thin layer me
 mbranes made by aluminum\, both free-standing and supported by a nanometri
 c thickness of SiO2\, embedded in a silicon frame. Membranes were fabricat
 ed with variable SiO2 and aluminum thicknesses according the route schemat
 ized in Fig. 1(b)\, which combines photolithography\, thin layer depositio
 n techniques\, wet and dry etching. Both wafer sides were processed in suc
 h a way to obtain\, on front side\, the openings for the aluminum membrane
 s which are then deposited by sputtering on the back side\, with thickness
 es equal to 0.25\, 0.5 and 1 micron\, respectively. Some of the obtained t
 argets are shown in Fig.1(c) characterized by optical\, electron\, and con
 focal microscopy. Individual targets contain up to 16\, 1 mm2 membranes av
 ailable for experiments\, and were used for laser-plasma experiments at th
 e laser installation of Proton Laser Applications\, S.L.\, which has devel
 oped a table-top laser system running at 3 TW with an intrinsic repetition
  rate up to 100 Hz [3]. The experimental setup is schematized in Fig. 1(d)
  showing in detail the interaction chamber where targets are easily locate
 d thanks to a purpose made holder which carries up to 16 individual target
 s\, resulting in 256 membranes available for consecutive shots. Results of
  preliminary experiments\, represented in Fig.1 (e) for 0.5 μm aluminum m
 embranes\, show the achievement of successful proton acceleration up to 2 
 MeV almost constant within the spanned focal plane (distances from focus p
 osition are listed in the legend\, in microns)\, and having the peak value
  in the focus\, as expected. This maximum energy is slightly higher than p
 revious results from plain foils\, and corresponds to the expectations wit
 h respect to the laser energy on target. We expect to improve this perform
 ance by further developments of our system directed from one side to incre
 ase the laser pulse energy\, and from the other\, to involve more sophisti
 cated target designs with micro-nano texturized surfaces which\, according
  to particle-in-cell simulations [4]\, should improve the coupling\, and t
 hus\, the acceleration results.\n\nhttps://indico.ific.uv.es/event/2851/co
 ntributions/4205/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4205/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Estimation of the radiobiological impact on non-small-cell lung ca
 ncer treatment plannings due to dose calculation algorithm
DTSTART;VALUE=DATE-TIME:20170719T153000Z
DTEND;VALUE=DATE-TIME:20170719T154500Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4197@indico.ific.uv.es
DESCRIPTION:Speakers: Álvaro Perales (Universidad de Sevilla)\nIntroducti
 on\n      The modeling of tissue heterogeneities and photon fluences for c
 omplex treatment plans in radiotherapy has been reported as the main sourc
 e of discrepancy in dose calculation [1]. Dose distribution disagreements 
 between Monte Carlo (MC) and treatment planning system (TPS) calculations 
 produce significant variations in the estimation of tumor control probabil
 ity (TCP) [2]. Hence for a complete treatment planification including radi
 obiological parameters we have to obtain an accurate calculation of the do
 se distribution.\n      Our purpose is to assess radiobiological variation
 s of lung cancer treatment plans due to divergences between dose distribut
 ions calculated by Pinnacle³ TPS (version 9.8)\, employed at the Hospital
  Universitario Virgen Macarena (Seville\, Spain)\, and by the Geant4 MC to
 olkit (version 10.01.p01) [3\,4].\n\nMaterial and methods\n     Three clin
 ical cases (see Table 1) distinguished by their tumoral size and localizat
 ion were analysed. Each clinical case presents a treatment planification c
 omposed by 6 MV photon beams with a conventional fractionation\, i. e. 2 G
 y per fraction. This scheme was established in order to achieve a 66 Gy pr
 escribed dose to the 95% of the planning target volume (PTV). We have set 
 conformity index (CI) and homogeneity index (HI) [5] as key parameters for
  dose distribution comparisons between Pinnacle3 and Geant4. \n      In ad
 dition to this dose analysis\, we have calculated TCP according to the lin
 eal-quadratic (LQ) model [6]. For this task we have used an alpha value of
  0.3 Gy-1\, a beta value of 0.03 Gy-2 and a density of clonogenic cells of
  10^7 cells/cm3. \n      For TPS calculations we have applied the Collapse
 d Cone algorithm and a voxel resolution of   2 x 2 x 2 mm³. In our MC cal
 culations we have simulated 2•10^10 events per clinical case. The scorin
 g volume dimensions were equal to patient DICOM image files resolution\, i
 . e. 0.937 x 0.937 x 5 mm³. These files were exported from the TPS for ev
 ery single treatment plan.\n\nResults\n      In Table 2 we have summarized
  the CI\, HI and TCP values calculated with Geant4 and Pinnacle3 for each 
 clinical case. Furthermore\, we have obtained variations of absorbed dose 
 at the 95% of the PTV (between Geant4 and TPS dose calculations) up to 2.3
  Gy for the clinical case 1. In this case\, a gamma analysis [7] between c
 alculated dose distributions with Geant4 and TPS (Fig. 1)\, done with acce
 ptance criteria of 3%-3mm\, gave a passing rate of 78.3% within the patien
 t. This evaluation was done utilizing Monte Carlo Treatment Planning (MCTP
 ) CARMEN [8\,9].\n\nDiscusion and conclusions\n     In all clinical cases 
 we have found more heterogeneous dose distributions employing Geant4 as ca
 lculation system. HI and CI values show us that dose calculations depend o
 n the particular clinical case. For clinical case 1 we have done a gamma a
 nalysis (3%-3 mm)\, which shows high discrepancies (red points which do no
 t satisfied gamma criteria) at the dose maximum zone which is inside PTV. 
 Dose divergences\, expressed through HI and CI values\, gave variations in
  TCP close to 4% between Geant4 and TPS calculations. In our methodology w
 e have used the LQ model with an alpha/beta ratio of 10 Gy and a constant 
 clonogenic cells density of 10^7 cells/cm3. A further study including more
  sophisticated radiobiology models and hypofractionated radiotherapy schem
 es will is ongoing.\n\nAcknowledgments\n    This work was funded in part b
 y the Spanish Ministry of Economy and Competitiveness (under projects no. 
 FPA2014-53290-C2-2-P and FPA2016-77689-C2-1-R) and by Junta de Andalucía 
 (under project no. P12-FQM-1605). The MC simulations were performed with o
 ur FIS-ATOM computing cluster\, hosted at Centro Informático y Científic
 o de Andalucía (CICA\, Seville\, Spain).\n\nReferences\n[1] B. Vanderstra
 eten\, et al. Medical Physics 33 (2006) 3149.\n[2] I. J. Chetty et al. Rad
 iother. Oncol. 109 (2013) 498.\n[3] S. Agostinelli et al. Nucl. Instrum. M
 eth. A 506 (2003) 250.\n[4] J. Allison et al. Nucl. Instrum. Meth. A 835 (
 2016) 225.\n[5] ICRU Report 83. Prescribing\, recording\, and reporting in
 tensity-modulated photon-beam therapy (IMRT). 2010. \n[6] J. F. Fowler Br.
  J. Radiol. 62 (1989) 679.\n[7] D. Low et al. Medical Physics 25 (1998) 65
 6.\n[8] A. Ureba et al. Medical Physics 41 (2014) 081719-1.\n[9] J. A. Bae
 za et al. Medical Physics 42 (2015) SU-E-T-157.\n\nhttps://indico.ific.uv.
 es/event/2851/contributions/4197/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4197/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Design concept and pilot tests of dedicated two panels prostate PE
 T
DTSTART;VALUE=DATE-TIME:20170719T141500Z
DTEND;VALUE=DATE-TIME:20170719T143000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4129@indico.ific.uv.es
DESCRIPTION:Speakers: Cañizares-Ledo Gabriel (I3M)\nThe main goal of this
  project (called PROSPET) is the development of a PET system for early dia
 gnostic\, treatment and following prostate cancer (PCa). It will also allo
 w us for PCa biopsy guiding using real time PET. We aim to significantly i
 mprove the efficiency and the spatial resolution in the detection of PCa\,
  when compared to whole body PET scanners. The design of this dedicated PE
 T is based on two panels of detectors surrounding the patient abdomen (nea
 ring the hip). In order to estimate the improvement and to evaluate possib
 le artefacts due to the particular design\, we have run simulations using 
 GATE\, a Geant4 platform.\n\nhttps://indico.ific.uv.es/event/2851/contribu
 tions/4129/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4129/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Electromagnetic metamaterials for magnetic resonance imaging in me
 dicine
DTSTART;VALUE=DATE-TIME:20170719T143000Z
DTEND;VALUE=DATE-TIME:20170719T144500Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4090@indico.ific.uv.es
DESCRIPTION:Speakers: Manuel Freire (Universidad de Sevilla)\nMetamaterial
 s are artificial composites whose electromagnetic properties can be engine
 ered to achieve any value of effective permittivity and/or permeability. M
 etamaterials can be designed with a negative permittivity/permeability to 
 behave as a lens for the electric/ magnetic field. The ability of metamate
 rial lenses with negative permeability to increase the signal-to-noise rat
 io (SNR) in magnetic resonance imaging (MRI) has been investigated. Moreov
 er\, it has been also analyzed the ability of metamaterial slabs with zero
 /high permeability to reject/confine the RF magnetic field in MRI systems 
 and thus to locally increase the SNR. Finally\, the ability of metamateria
 l lenses to localize the field of view of MRI coils in an array and thus t
 o reduce the noise correlation has been also investigated. This has applic
 ation in parallel MRI to reduce the acquisition time of the image.\n\nhttp
 s://indico.ific.uv.es/event/2851/contributions/4090/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4090/
END:VEVENT
BEGIN:VEVENT
SUMMARY:Complete Validation of Biograph mCT PET with Monte Carlo simulatio
 n: GATE and STIR.
DTSTART;VALUE=DATE-TIME:20170719T134500Z
DTEND;VALUE=DATE-TIME:20170719T140000Z
DTSTAMP;VALUE=DATE-TIME:20260714T184740Z
UID:indico-contribution-551-4072@indico.ific.uv.es
DESCRIPTION:Speakers: Lorena Vázquez Canelas (Universidad de Salamanca)\n
 The Geant Application for Tomographic Emission (GATE) is a simulation plat
 form based on GEANT4\, which is designed to perform numerical simulation i
 n medical imaging and radiotherapy. The purpose of our study is to validat
 e a GATE model of the commercial PET/CT Siemens Biograph placed at the Uni
 versity Hospital of Salamanca (Spain). The geometry of the system was impl
 emented including the detector ring\, crystal blocks\, PMTs\,etc. The GATE
  simulation results were  reconstructed with analytical and iterative algo
 rithms using STIR (Software for Tomographic Image Recostruction)\, an open
  source software for 3D PET and SPECT image reconstruction. Simulated data
  were compared to experimental results obtanied using the NEMA NU-2-2007 s
 tandard protocols. It consisted of sensitivity estimation\, count rate\, N
 EC curve\, scatter fraction\, spatial resolution and image quality (hot an
 d cold contrasts\, atenuation in the lung and percent background variabili
 ty).\nThe reults for 2D and 3D sensitivity\, scatter fraction\, count rate
  and parameters referring to the image quality were found to agree with ex
 perimental values. The simulated sensitivity obtained is 10.9 cps/kBq in t
 he center of the transaxial field of view and 8.85 cps/kBq at 10cm. Excell
 ent agreement between simulation and experiment can be seen in the spatial
  resolution results\, FWHM being 5.288 mm at 1 cm with GATE and 5.280 mm a
 t 1 cm experimentally. Simulated Scatter dispersion was 35.1% for a concen
 tration of 2.48 kBq/mL\, a value was lower than that provided by the manuf
 acturer.\nIn conclusion\, our study showed that our Monte Carlo model can 
 be used to optimize\,simplify and reduce the simulation time for the quali
 ty control procedure of PET scanners.\n\nhttps://indico.ific.uv.es/event/2
 851/contributions/4072/
LOCATION:Facultad de Química (USC) Aula Química Orgánica
URL:https://indico.ific.uv.es/event/2851/contributions/4072/
END:VEVENT
END:VCALENDAR
