BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:The STAR Heavy Flavor Tracker (HFT)
DTSTART;VALUE=DATE-TIME:20140705T132000Z
DTEND;VALUE=DATE-TIME:20140705T134000Z
DTSTAMP;VALUE=DATE-TIME:20261119T031002Z
UID:indico-contribution-1170@indico.ific.uv.es
DESCRIPTION:Speakers: Giacomo Contin (Lawrence Berkeley National Laborator
 y - LBNL)\nThe heavy quark hadrons are suggested as a clean probe for stud
 ying the early dynamic evolution of the dense and hot medium created in hi
 gh-energy nuclear collisions. \nThe Heavy Flavor Tracker (HFT) of the STAR
  experiment\, designed to improve the vertex resolution and extend the mea
 surement capabilities in the heavy flavor domain\, was installed for the 2
 014 heavy ion run of RHIC. \nIt is composed of three different silicon det
 ectors arranged in four concentric cylinders close to the STAR interaction
  point. The two innermost layers are based on CMOS monolithic active pixel
 s (MAPS)\, featured for the first time in a collider experiment\, and the 
 two outer layers are based on pads and strips.\nThe two innermost HFT laye
 rs are placed at a radius of 2.7 and 8 cm from the beam line and accommoda
 te 400 ultra-thin (50 um) high resolution MAPS sensors arranged in 10-sens
 or ladders to cover a total silicon area of 0.16 m2. Each sensor includes 
 a pixel array of 928 rows and 960 columns with a 20.7 μm pixel pitch\, pr
 oviding a sensitive area of ~ 3.8 cm2. The sensor features 185.6 μs reado
 ut time and 170 mW/cm2 power dissipation. \nThe detector is air-cooled\, a
 llowing a global material budget of 0.50% radiation length per layer. A no
 vel mechanical approach to detector insertion enables effective installati
 on and integration of the pixel layers within an 8 hour shift during the o
 n-going STAR Run.\nAfter a detailed description of the design specificatio
 ns and the technology implementation\, the detector status and operations 
 during the current 200 GeV Au+Au run will be presented in this talk\, with
  a particular focus on calibration and general system operations aimed at 
 stabilizing the running conditions. \nA preliminary estimation of the dete
 ctor performance meeting the design requirements will be reported.\n\nhttp
 s://indico.ific.uv.es/event/2025/contributions/1170/
LOCATION: Auditorium 3B
URL:https://indico.ific.uv.es/event/2025/contributions/1170/
END:VEVENT
END:VCALENDAR